Olympus Stylus 410 Logic Board Replacement

ID: 2472

Description: If your Olympus Stylus 410 no longer functions...

Steps:

  1. Locate the 2 screws on the bottom of the slider.
  2. Remove both screws with a #00 Phillips screwdriver.
  3. Step image
  4. Gently pull on the bottom of the slider until it comes off the lower track.
  5. There is a little piece that connects the slider to the track. Be sure not to lose this as it is needed to put the slider back on.
  6. Step image
  7. Lift the slider up until it comes off the upper track.
  8. Step image
  9. The slider should now be free from the body of the camera.
  10. Step image
  11. Locate the 3 screws on the outer metal band and remove them with a #00 Phillips screwdriver.
  12. Step image Step image Step image
  13. Use the spudger to peel off the outer metal band, starting from the bottom of the camera.
  14. The metal band it attached to the camera with glue in addition to screws. Be careful not to bend the band when removing it from the camera.
  15. Step image Step image
  16. The shutter button can now be removed. It is not connected to the camera and can be lifted off.
  17. Step image Step image
  18. Remove the memory card.
  19. Locate and remove the 2 screws using a #00 Phillips screwdriver.
  20. Step image Step image
  21. Use a spudger around the edge of the case to loosen it.
  22. Carefully wiggle the back case off. This may require a fair amount of force.
  23. Step image Step image Step image
  24. Locate the 3 internal screws holding on the front of the case. Remove them with a #00 Phillips screwdriver.
  25. Step image
  26. While grasping the interior and the front case, gently pull until they start to come apart. Some light wiggling may be required.
  27. Be careful not to completely pull the front case off because it will still be connected with wires.
  28. Step image Step image